Publication date: Available online 7 August 2018
Source: Injury
Author(s): Cesar de Cesar Netto, Martim Pinto, Lauren Roberts, Sung Ro Lee, Andrew R. Roney, Sameer Naranje, Alexandre Leme Godoy-Santos, Ashish Shah
ABSTRACT
Introduction
Precise diagnosis of distal tibiofibular syndesmotic injury is challenging, and a gold standard diagnostic test has still not been established. Tibiofibular clear space identified on radiographic imaging is considered the most reliable indicator of the injury. The Cotton test is the most widely used intraoperative technique to evaluate the syndesmotic integrity although it has its limitations. We advocate for a novel intra operative test using a 3.5 mm blunt cortical tap.
Methods
Tibiofibular clear space was assessed in nine cadaveric specimens using three sequential fluoroscopic images. The first image was taken prior to the application of the tap test (intact, non-stressed). Then, a 2.5 mm hole was drilled distally on the lateral fibula, and a 3.5 mm cortical tap was then threaded in the hole. The tap test involved gradually advancing the blunt tip against the lateral tibia, providing a tibiofibular separation force (intact, stressed). This same stress was then applied after all syndesmotic ligaments were released (injured, stressed). Measurements were compared by one-way ANOVA and paired Student's t-test. Intra and inter-observer agreements were evaluated by intraclass correlation coefficient (ICC). P-values <.05 were considered significant.
Results
We found excellent intra-observer (0.97) and inter-observer (0.98) agreement following the imaging assessment. Significant differences were found in the paired comparison between the groups (p < .05). When using an absolute value for TFCS >6 mm as diagnostic for coronal syndesmotic instability, the tap test demonstrated a 96.3% sensitivity and specificity, a 96.3% PPV and NPV and a 96.3% accuracy in diagnosing coronal syndesmotic instability.
Conclusions
Our cadaveric study demonstrated that this novel coronal syndesmotic instability test using a 3.5 mm blunt cortical tap is a simple, accurate and reliable technique able to demonstrate significant differences in the tibiofibular clear space when injury was present. It could represent a more controlled and stable alternative to the most used Cotton test.