Abstract
Objectives
The purpose of this study was to compare the diagnostic value of a one-step to a two-step staging algorithm utilizing 18F-FDG PET/MRI in breast cancer patients.
Methods
A total of 38 patients (37 females and one male, mean age 57 ± 10 years; range 31–78 years) with newly diagnosed, histopathologically proven breast cancer were prospectively enrolled in this trial. All PET/MRI examinations were assessed for local tumor burden and metastatic spread in two separate reading sessions: (1) One-step algorithm comprising supine whole-body 18F-FDG PET/MRI, and (2) Two-step algorithm comprising a dedicated prone 18F-FDG breast PET/MRI and supine whole-body 18F-FDG PET/MRI.
Results
On a patient based analysis the two-step algorithm correctly identified 37 out of 38 patients with breast carcinoma (97%), while five patients were missed by the one-step 18F-FDG PET/MRI algorithm (33/38; 87% correct identification). On a lesion-based analysis 56 breast cancer lesions were detected in the two-step algorithm and 44 breast cancer lesions could be correctly identified in the one-step 18F-FDG PET/MRI (79%), resulting in statistically significant differences between the two algorithms (p = 0.0015). For axillary lymph node evaluation sensitivity, specificity and accuracy was 93%, 95 and 94%, respectively. Furthermore, distant metastases could be detected in seven patients in both algorithms.
Conclusion
The results demonstrate the necessity and superiority of a two-step 18F-FDG PET/MRI algorithm, comprising dedicated prone breast imaging and supine whole-body imaging, when compared to the one-step algorithm for local and whole-body staging in breast cancer patients.
https://ift.tt/2LFotKS
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.