Αρχειοθήκη ιστολογίου

Αναζήτηση αυτού του ιστολογίου

Τρίτη 26 Ιουνίου 2018

Sensitivity and Specificity of Patient-Entered Red Flags for Lower Back Pain

Publication date: Available online 26 June 2018
Source:The Spine Journal
Author(s): John T. Tsiang, Tyler G. Kinzy, Nicolas Thompson, Joseph E. Tanenbaum, Nitya L. Thakore, Tagreed Khalaf, Irene L. Katzan
Background Content: Red flags are questions typically ascertained by providers to screen for serious underlying spinal pathologies. The utility of patient-reported red flags in guiding clinical decision-making for spine care, however, has not been studied.Purpose: The aim of this study was to quantify the sensitivity and specificity of patient-reported red flags in predicting the presence of serious spinal pathologies.Study Design: This was a retrospective nested case-control studyPatient Sample: This study consisted of 120 patients with ICD-9-CM codes for spinal pathologies and 380 randomly selected patients, from a population of 4,313 patients seen at a large tertiary care spine clinic between Oct. 9, 2013 and June 30, 2014.Outcome Measures: The presence of patient-reported red flags and red flags obtained from medical records was verified for chart review. The spinal pathology (i.e., malignancy, fractures, infections, or cauda equina syndrome) was noted for each patient.Methods: The sensitivity and specificity of patient-reported red flags for detecting serious spinal pathologies were calculated from data obtained from the 500 patients. Youden's J was used to rank performance. Agreement between patient-reported red flags and those obtained from medical record review was assessed via Cohen's kappa statistic.Results: "History of cancer" was the best performing patient-reported red flag to identify malignancy [sensitivity=.75 (95%CI .53-.90), specificity=.79 (95%CI .75-.82)]. The best performing patient-reported red flag for fractures was the presence of at least one of the following: "Osteoporosis", "Steroid use", and "Trauma" [sensitivity=.59 (95%CI .44-.72), specificity=.65 (95%CI .60-.69)]. The prevalence of infection and cauda equina diagnoses was insufficient to gauge sensitivity and specificity. Red flags from medical records had better performance than patient-reported red flags. There was poor agreement between patient red flags and those obtained from medical record review.Conclusion: Patient-reported red flags had low sensitivity and specificity for identification of serious pathologies. They should not be used in insolation to make treatment decisions, although they may be useful to prompt further probing to determine if additional investigation is warranted.



https://ift.tt/2Km2E2p

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.