Metal Allergy in Tracheostomy Tube Placement Resulting in Complete Subglottic Stenosis: A Case Report

xlomafota13 shared this article with you from Inoreader

pubmed-meta-image.png

Ann Otol Rhinol Laryngol. 2022 Jan 6:34894211070135. doi: 10.1177/00034894211070135. Online ahead of print.

ABSTRACT

OBJECTIVES: Metal hypersensitivity reaction to surgical implants is a well- known phenomenon that is associated with pain, swelling, inflammation, and decreased efficacy of the implant. We present a unique case of a patient with placement a metal Jackson tracheostomy tube that led to expeditious total subglottic stenosis.

METHODS: The patient was a 33-ye ar old, severely atopic woman with history of asthma exacerbations requiring several intubations for acute respiratory failure with several subsequent tracheal dilations with steroid injections, and eventual tracheostomy placement with a metal Jackson tracheostomy tube that led to expeditious total subglottic stenosis.

RESULTS: Initial intervention included performing an airway evaluation, CO2 laser, and steroid injection of the area of complete subglottic stenosis. Follow up several months later revealed little improvement in level of tracheal narrowing proximal to the tracheostomy tube. Patient did not have shortness of breath but continued to be aphonic. Cricotracheal versus tracheal resection have been proposed but surgical morbidity was deemed too high due to patient's obesity.

CONCLUSIONS: Metal hypersensitivity reactions are well known phenomena as it relates to surgical implants in other surgical specialties but are seldom reported within the ear, nose and throat literature. Oftentimes, it takes astute observation to diagnose and establish a connection. Prompt recognition and treatment can be acquired from interdisciplinary collaboration with allergy.

PMID:34991357 | DOI:10.1177/00034894211070135

View on the web

Management strategies for chronic rhinosinusitis with nasal polyps

xlomafota13 shared this article with you from Inoreader
Via hno

pubmed-meta-image.png

HNO. 2022 Jan 7. doi: 10.1007/s00106-021-01127-9. Online ahead of print.

ABSTRACT

Chronic rhinosinusitis with (CRwNP) or without (CRsNP) nasal polyps can have a great impact on quality of life. Typical symptoms include nasal obstruction, olfactory dysfunction, nasal discharge, and facial pain or pressure. Diagnostic gold standard is nasal endoscopy followed by CT scan of the paranasal sinuses. Besides first-line treatment with topical or systemically applied glucocorticoids, nasal rinsing, and surgical therapy, monoclonal antibodies have been approved in Germany since 2019.

PMID:34994808 | DOI:10.1007/s00106-021-01127-9

View on the web

Induction and generalization of nocebo effects on itch

xlomafota13 shared this article with you from Inoreader

Abstract

Nocebo effects, i.e., negative treatment outcomes due to negative expectancies, can increase itch. Moreover, indirect evidence has shown that nocebo hyperknesis can generalize to another itch modality. Knowledge on response generalization can help to prevent and decrease negative effects. The aims of this study were to investigate 1) the efficacy of inducing nocebo effects on cowhage-evoked itch via verbal suggestions and 2) whether these effects can generalize to 2a) mechanically evoked touch and 2b) mechanically evoked itch. Forty-four healthy participants watched a video suggesting that a nocebo solution increases cowhage-evoked itch and that a control solution does not affect itch. Subsequently, cowhage, mechanical itch, and mechanical touch stimuli were applied. Nocebo effects were measured as the difference in both mean and peak of the outcomes itch and urge to scratch between nocebo and control trials. Main analyses revealed significant nocebo effects on mean and peak itch for all stimuli. For urge to scratch, a significant nocebo effect was only observed for mechanical touch (peak). As mechanical stimuli did not induce pure sensations as planned, post-hoc sensitivity analyses were run for mechanical stimuli that individually induced either touch or itch at baseline. These analyses showed similar results for generalization to mechanical itch, but generalization to mechanical touch was nonsignificant. This study showed that merely verbal suggestion can induce nocebo effects on cowhage-evoked itch and that these effects can generalize to another itch modality. Future studies may examine how to prevent negative experiences from generalizing to subsequent encounters.

View on the web

Πέμπτη 6 Ιανουαρίου 2022

Disulfiram Exerts Antiadipogenic, Anti-Inflammatory, and Antifibrotic Therapeutic Effects in an In Vitro Model of Graves' Orbitopathy

xlomafota13 shared this article with you from Inoreader

showCoverImage?journalCode=

Thyroid, Ahead of Print.
View on the web

Characterizing Polarity Sensitivity in Cochlear Implant Recipients: Demographic Effects and Potential Implications for Estimating Neural Health

xlomafota13 shared this article with you from Inoreader

Abstract

Stimulus polarity can affect both physiological and perceptual measures in cochlear-implant recipients. Large differences between polarities for various outcome measures (e.g., eCAP threshold, amplitude, or slope) theoretically reflect poorer neural health, whereas smaller differences reflect better neural health. Therefore, we expect large polarity effects to be correlated with other measures shown to contribute to poor neural health, such as advanced age or prolonged deafness. Our earlier studies using the electrically evoked compound action potential (eCAP) demonstrated differences in polarity effects between users of Cochlear and Advanced Bionics devices when device-specific clinical pulse designs were used. Since the stimuli differed slightly between devices, the first goal of this study was to determine whether small, clinically relevant differences in pulse phase duration (PD) have a significant impact on eCAP polarity effects to potentially explain the de vice differences observed previously. Polarity effects were quantified as the difference in eCAP thresholds, mean normalized amplitudes, and slope of the amplitude growth function obtained for anodic-first versus cathodic-first biphasic pulses. The results showed that small variations in PD did not explain the observed differences in eCAP polarity effects between devices. Therefore, eCAP polarity sensitivity measures are relatively robust to small differences in pulse parameters. However, it remains unclear what underlies the observed manufacturer differences, which may limit the utility of eCAP polarity sensitivity measures. The second goal was to characterize polarity sensitivity in a large group of CI recipients (65 ears) to relate polarity sensitivity to age and duration of deafness as a proxy for neural health. The same pulse parameters were used for both device groups. The only significant predictors of eCAP polarity effects were age for threshold and amplitude polarity effect s for Cochlear recipients and age and duration of deafness for slope for AB recipients. However, three of these four correlations were in the opposite direction of what was expected. These results suggest that eCAP polarity sensitivity measures likely reflect different mechanisms than the effects that age and duration of deafness induce on the peripheral auditory system.

View on the web

Temporomandibular Disorders Core Curriculum for Predoctoral Dental Education: Recommendations from the American Academy of Orofacial Pain

xlomafota13 shared this article with you from Inoreader

pubmed-meta-image.png

J Oral Facial Pain Headache. 2021 Fall;35(4):271-277. doi: 10.11607/ofph.3073.

NO ABSTRACT

PMID:34990495 | DOI:10.11607/ ofph.3073

View on the web

Τρίτη 4 Ιανουαρίου 2022

Formaldehyde-hardened albumin as a non-penetrating embedding matrix for frozen and vibratome sectioning

xlomafota13 shared this article with you from Inoreader
Via histochem

pubmed-meta-image.png

Acta Histochem. 2021 Dec 31;124(1):151838. doi: 10.1016/j.acthis.2021.151838. Online ahead of print.

ABSTRACT

In this paper, we describe a protocol for a non-penetrating embedding matrix that can be used for frozen or vibratome sectioning of various formaldehyde-fixed tissue specimens. In our experiments, we wanted to prepare thin frozen sections from miniature specimens for fluorescent staining. As we could not achieve satisfactory results with any of the previously publish ed methods, we have tried to modify the existing protocols, and systematically evaluated the effect of these modifications on the properties of the embedding matrix. The resulting protocol is simple, the matrix gets firmly attached to the tissues, does not cause autofluorescence and enables preparing extremely thin frozen sections. The matrix can be used for 1, embedding miniature specimens from problematic tissues to enable cutting very thin frozen sections, 2, grouping multiple specimens into one large block for simultaneous processing, and 3, dispersing single cells and preparing cell blocks for frozen sectioning.

PMID:34979375 | DOI:10.1016/j.acthis.2021.151838