Kiyoshi Yaoeda,1,2 Atsushi Fukushima,1 Motohiro Shirakashi,3 Takeo Fukuchi2
1Yaoeda Eye Clinic, Nagaoka, 2Division of Ophthalmology and Visual Sciences, Niigata University Graduate School of Medical and Dental Sciences, 3Kido Eye Clinic, Niigata, Japan
Purpose: To investigate the correlation coefficients between intraocular pressure (IOP) before and after adjusting for central corneal thickness (CCT) and corneal biomechanical properties.
Patients and methods: A total of 218 eyes of 218 patients with primary open-angle glaucoma (mean age =71.5 years; mean spherical equivalent =-0.51 D; mean deviation determined by Humphrey visual field analyzer =-3.22 dB) were included in this study. The tIOP and tIOPCCT, which were adjusted by the CCT (with tIOP meaning IOP not adjusted by CCT, as determined using the CT-1P; and tIOPCCT meaning IOP adjusted by CCT, as determined using the CT-1P), were determined using a noncontact tonometer. The IOPg and IOPCCT, which were adjusted by CCT, and IOPcc adjusted by corneal biomechanical properties were determined using a Reichert 7CR (with IOPg meaning IOP not adjusted by CCT or corneal biomechanical properties, as determined using the Reichert 7CR; IOPCCT meaning IOP adjusted by CCT, as determined using the Reichert 7CR; and IOPcc meaning IOP adjusted by corneal biomechanical properties, as determined using the Reichert 7CR). The GT and GTCCT adjusted by CCT were determined using a Goldmann applanation tonometer (with GT meaning IOP not adjusted by CCT, as determined using the Goldmann applanation tonometer; and with GTCCT meaning IOP adjusted by CCT, as determined using the GAT). Pearson's correlation coefficients among the IOPs were calculated and compared. P-values <0.05 were considered as statistically significant.
Results: The tIOP, tIOPCCT, IOPg, IOPCCT, IOPcc, GT, and GTCCT were 14.8±2.5, 15.0±2.4, 13.1±3.2, 13.3±3.1, 13.7±2.9, 13.2±2.4, and 13.4±2.3 mmHg (mean ± standard deviation), respectively. The correlation coefficient between tIOPCCT and tIOP (r=0.979) was significantly higher than that between tIOPCCT and the other IOPs (r=0.668–0.852; P<0.001, respectively). The correlation coefficient between IOPCCT and IOPg (r=0.994) or IOPcc and IOPg (r=0.892) was significantly higher than that between IOPCCT or IOPcc and the other IOPs (r=0.669–0.740; P<0.001, respectively). The correlation coefficient between GTCCT and GT (r=0.989) was significantly higher than that between GTCCT and the other IOPs (r=0.669–0.740; P<0.001, respectively).
Conclusion: The IOP adjusted by CCT or corneal biomechanical properties depends on the measurement instrument itself, rather than the adjustment methods, for eyes of patients with primary open-angle glaucoma.
Keywords: ocular response analyzer, corneal biomechanical property, corneal hysteresis, glaucoma, intraocular pressure
from #Medicine via ola Kala on Inoreader http://ift.tt/1T7hdRh
via IFTTT
Αρχειοθήκη ιστολογίου
-
►
2023
(138)
- ► Φεβρουαρίου (74)
- ► Ιανουαρίου (64)
-
►
2022
(849)
- ► Δεκεμβρίου (61)
- ► Σεπτεμβρίου (74)
- ► Φεβρουαρίου (65)
-
►
2021
(2936)
- ► Δεκεμβρίου (59)
- ► Σεπτεμβρίου (180)
- ► Φεβρουαρίου (325)
-
►
2020
(1624)
- ► Δεκεμβρίου (293)
- ► Σεπτεμβρίου (234)
- ► Φεβρουαρίου (28)
-
►
2019
(13362)
- ► Δεκεμβρίου (19)
- ► Σεπτεμβρίου (54)
- ► Φεβρουαρίου (5586)
- ► Ιανουαρίου (5696)
-
►
2018
(66471)
- ► Δεκεμβρίου (5242)
- ► Σεπτεμβρίου (5478)
- ► Φεβρουαρίου (4835)
- ► Ιανουαρίου (5592)
-
►
2017
(44259)
- ► Δεκεμβρίου (5110)
- ► Σεπτεμβρίου (5105)
-
▼
2016
(7467)
- ► Δεκεμβρίου (514)
- ► Σεπτεμβρίου (1038)
-
▼
Μαΐου
(630)
-
▼
Μαΐ 22
(46)
- Clinical utility of the KAMRA corneal inlay
- Time of maximum cycloplegia after instillation of ...
- Ranibizumab in monotherapy and combined with photo...
- Segmentation and removal of fibrovascular membrane...
- Neurofibromatosis: an update of ophthalmic charact...
- Tear volume estimation using a modified Schirmer t...
- Ocular manifestations of Sturge–Weber syndrome: pa...
- The IMPACT study: a prospective evaluation of the ...
- An exploratory study evaluating the effects of mac...
- Pre- and postsynaptic effects of brimonidine on is...
- Comparison of intraocular pressure adjusted by cen...
- Comparison of visual outcomes and subjective visua...
- A randomized, double-blind, placebo-controlled stu...
- Effect of benzalkonium chloride-free latanoprost o...
- A nonrandomized, open-label study to evaluate the ...
- Risk factors for visual impairment associated with...
- Pharmacokinetics and aqueous humor penetration of ...
- Outcomes of excimer laser enhancements in pseudoph...
- Feasibility study of sustained-release travoprost ...
- Vitrectomy for center-involved diabetic macular edema
- Glycan Node Analysis: A Bottom-up Approach to Glyc...
- Light-driven Enzymatic Decarboxylation
- Assessment of Startle Response and Its Prepulse In...
- Plasma miR-10a: A Potential Biomarker for Coronary...
- Two-Year Follow-Up after Contact Force Sensing Rad...
- The Utility of a Digital Virtual Template for Juni...
- A Review of Animal Models of Intervertebral Disc D...
- Volatiles from Subtropical Convolvulaceae That Int...
- Unveiling alterative splice diversity from human o...
- Proteomic characterization of Nα- and Nε-acetylati...
- A proteomic signature of ovarian cancer tumor flui...
- Transcriptomic and proteomic analyses provide new ...
- A cost-effective method to get insight into the pe...
- Screening for target toxins of the antiophidic pro...
- Oncogenic KIT mutations in different exons lead to...
- From great kivas to great houses: Community format...
- Antigenic characterization of influenza viruses pr...
- A national examination of pharmacy-based immunizat...
- Report of the Cent Gardes HIV Vaccines Conference....
- The impact of implementing a demand forecasting sy...
- Humoral, T-cell and B-cell immune responses to sea...
- Effectiveness of seasonal trivalent influenza vacc...
- Ultrastructural Changes and Death of Leishmania in...
- Responding to the existentials of non-life-threate...
- Home-applied IPL epilation may prevent the problem...
- General vulnerability to stuttering: The experienc...
-
▼
Μαΐ 22
(46)
- ► Φεβρουαρίου (793)
Αναζήτηση αυτού του ιστολογίου
Κυριακή 22 Μαΐου 2016
Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
-
Αλέξανδρος Γ. Σφακιανάκης Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,0030693260717...
-
heory of COVID-19 pathogenesis Publication date: November 2020Source: Medical Hypotheses, Volume 144Author(s): Yuichiro J. Suzuki ScienceD...
-
Alimentary Pharmacology &Therapeutics, EarlyView. https://ift.tt/2qECBIJ
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.