The outcome of intracapsular hip fracture fixation using the Targon Femoral Neck (TFN) locking plate system or cannulated cancellous screws: A comparative study involving 2004 patients

Publication date: Available online 1 September 2017
Source:Injury
Author(s): Zeiad Alshameeri, Mohamed Elbashir, Martyn J. Parker
AimThis study compares the outcome of intracapsular hip fracture fixation using the Targon Femoral Neck (TFN) locking plate system with the standard fixation using cannulated cancellous screws (CCS).Patients and MethodAnalyses of a prospectively collected data of all patients treated for intracapsular hip fractures using the TFN system and CCS at our department over a period of 28 years. Baseline characteristics and specific outcome measures where compared. The primary outcome measure was fracture revision during the 1st year. Secondary outcome measures were fracture complications, any revision surgery, mortality and mobility status at one year after surgery.ResultsA total of 2004 fractures were included, a third (n=725, 36.2%) were treated using the TFN system. There were higher rates of non-union (19.5% vs 9.5%) and revision surgery (19% vs 9%) during the first year in the CCS cohort. Revision surgery was also higher in the same group during the whole of the follow-up period (22.2% vs 14.9%). The first year's mortality rate was in the CCS cohort (21.1% vs 17.5%) but the reduction in mobility and mobility scores was the same in both cohorts.ConclusionThis study includes the largest cohort of cases treated for intracapsular hip fractures using the TFN system. It demonstrated that the TFN system was associated with lower rates of non-union, revisions and re-operations for any cause.



http://ift.tt/2wrFX52

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.