Abstract
Objectives
An epoxy resin worker developed hypersensitivity pneumonitis requiring lung transplantation and had an abnormal blood lymphocyte proliferation test (LPT) to an epoxy hardener. We assessed the prevalence of symptoms, abnormal spirometry, and abnormal epoxy resin LPT results in epoxy resin workers compared to unexposed workers.
Methods
Participants completed questionnaires and underwent spirometry. We collected blood for epoxy resin LPT and calculated stimulation indices for five epoxy resin products.
Results
We compared 38 exposed to 32 unexposed workers. Higher exposed workers were more likely to report cough (OR 10.86, [1.23-infinity], p = 0.030) or wheeze (OR 4.44, [1.00-22.25], p = 0.049) than unexposed workers, even controlling for smoking. Higher exposed workers were more likely to have abnormal FEV1 than unexposed workers (OR 10.51, [0.86-589.9], p = 0.071), although not statistically significant when adjusted for smoking. There were no differences in proportion of abnormal epoxy resin system LPTs between exposed and unexposed workers.
Conclusions
In summary, workers exposed to epoxy resin system chemicals were more likely to report respiratory symptoms and have abnormal FEV1 than unexposed workers. Use of epoxy resin LPT was not helpful as a biomarker of exposure and sensitization. Clin Trans Sci 2015; Volume #: 1–7