Αρχειοθήκη ιστολογίου

Αναζήτηση αυτού του ιστολογίου

Τετάρτη 22 Ιουνίου 2016

Volumetric Single-Beat Coronary Computed Tomography Angiography: Relationship of Image Quality, Heart Rate, and Body Mass Index. Initial Patient Experience With a New Computed Tomography Scanner.

Background: Cardiac computed tomography (CT) image quality (IQ) is very important for accurate diagnosis. We propose to evaluate IQ expressed as Likert scale, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) from coronary CT angiography images acquired with a new volumetric single-beat CT scanner on consecutive patients and assess the IQ dependence on heart rate (HR) and body mass index (BMI). Methods: We retrospectively analyzed the data of the first 439 consecutive patients (mean age, 55.13 [SD, 12.1] years; 51.47% male), who underwent noninvasive coronary CT angiography in a new single-beat volumetric CT scanner (Revolution CT) to evaluate chest pain at West Kendall Baptist Hospital. Based on patient BMI (mean, 29.43 [SD, 5.81] kg/m2), the kVp (kilovolt potential) value and tube current were adjusted within a range of 80 to 140 kVp and 122 to 720 mA, respectively. Each scan was performed in a single-beat acquisition within 1 cardiac cycle, regardless of the HR. Motion correction software (SnapShot Freeze) was used for correcting motion artifacts in patients with higher HRs. Autogating was used to automatically acquire systolic and diastolic phases for higher HRs with electrocardiographic milliampere dose modulation. Image quality was assessed qualitatively by Likert scale and quantitatively by SNR and CNR for the 4 major vessels right coronary, left main, left anterior descending, and left circumflex arteries on axial and multiplanar reformatted images. Values for Likert scale were as follows: 1, nondiagnostic; 2, poor; 3, good; 4, very good; and 5, excellent. Signal-to-noise ratio and CNR were calculated from the average 2 CT attenuation values within regions of interest placed in the proximal left main and proximal right coronary artery. For contrast comparison, a region of interest was selected from left ventricular wall at midcavity level using a dedicated workstation. We divided patients in 2 groups related to the HR: less than or equal to 70 beats/min (bpm) and greater than 70 bpm and also analyzed them in 2 BMI groupings: BMI less than or equal to 30 kg/m2 and BMI greater than 30 kg/m2. Results: Mean SNR was 8.7 (SD, 3.1) (n = 349) for group with HR 70 bpm or less and 7.7 (SD, 2.4) (n = 78) for group with HR greater than 70 bpm (P = 0.008). Mean CNR was 6.9 (SD, 2.7) (n = 349) for group with HR 70 bpm or less and 5.9 (SD, 2.2) (n = 78) for group with HR 70 bpm or greater (P = 0.002). Mean SNR was 8.8 (SD, 3.2) (n = 249) for group with BMI 30 kg/m2 or less and 8.1 (SD, 2.6) (n = 176) for group with BMI greater than 30 kg/m2 (P = 0.008). Mean CNR was 7.0 (SD, 2.8) (n = 249) for group with BMI 30 kg/m2 or less and 6.4 (SD, 2.4) (n = 176) for group with BMI greater than 30 kg/m2 (P = 0.002). The results for mean Likert scale values were statistically different, reflecting difference in IQ between people with HR 70 bpm or less and greater than 70 bpm, BMI 30 kg/m2 or less, and BMI greater than 30 kg/m2. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.

from #Medicine via ola Kala on Inoreader http://ift.tt/28PgV3d
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.